HomeProductsVertical Laminar Air Flow (Stand Mounted VLAF)
Vertical Laminar Air Flow (Stand Mounted VLAF)
Laminar Airflow
Finish: Electropolished Worktop (Ra < 0.4 µm)100% Traceable SS
Himalayan Steel Precision Series

Vertical Laminar Air Flow (Stand Mounted VLAF)

Engineered to establish an ultra-clean localized ISO Class 5 / Class 100 sterile working zone for sensitive pharmaceutical compounding, microbiology research, and sterile preparation. High-velocity unidirectional vertical airflow shields products against airborne cross-contamination.

Available Metallurgies
SS 316L WorktopSS 304 Structure
Regulatory Compliance
ISO 14644-1 Class 5 CertifiedUS Federal Standard 209EcGMP Sanitary Norms
✓ Direct factory prices•✓ Material Test Certificate (MTC 3.1) included•✓ Pan-India Delivery

Engineering Overview & Fluid Dynamics

Active contamination barrier and laminar downflow principles

The Himalayan Steel Vertical Laminar Air Flow (VLAF) workstation supplies unidirectional, uniform downward laminar airflow over an entire stainless steel work table at 0.45 ± 0.1 m/s. Room air enters via bottom pre-filters and is propelled through high-efficiency mini-pleat H14 HEPA filters located above the workspace. Because the air travels downwards through perforated work surfaces or exits via the front operator aperture, product protection is maximized while preventing cross-batch contamination.

Technical Engineering Specifications

Standard dimensional tolerances, electrical parameters, and air quality ratings

Cleanliness StandardISO 14644-1 Class 5 (Class 100 sterile zone)
Air Flow DirectionVertical unidirectional laminar downflow
Air Velocity0.45 ± 0.1 m/s (90 ± 20 FPM) uniform downflow
HEPA FilterMini-pleat H14 aluminum separator-less (99.997% @ 0.3 micron)
Pre-FilterWashable synthetic non-woven media with 90% arrestance (EU-4)
Work TableOne-piece seamless SS 316L with coved corners and perforated perimeter
Side Sashes6 mm clear anti-static acrylic or tempered safety glass
Front SashCounterbalanced sliding glass sash with parking lock mechanism
Differential GaugeDwyer Magnehelic® 0–50 mm WC monitoring filter loading
Noise Level< 65 dB(A) at operator working position

Standard Dimensional Matrix

Fabrication schedule comparison in Imperial and Metric standards

Custom dimensions available on request
Size (Feet)Metric (MM)Internal Chamber (W x D x H)External Footprint (W x D x H)
2 x 2 ft610 x 610 x 1800 mm610 x 610 x 650 mm760 x 780 x 1950 mm
3 x 2 ft (Standard Lab)915 x 610 x 1800 mm915 x 610 x 650 mm1065 x 780 x 1950 mm
4 x 2 ft (Pharma Benchmark)1220 x 610 x 1800 mm1220 x 610 x 650 mm1370 x 780 x 1950 mm
5 x 2 ft1524 x 610 x 1800 mm1524 x 610 x 650 mm1675 x 780 x 1950 mm
6 x 2 ft (Dual Operator)1830 x 610 x 1800 mm1830 x 610 x 650 mm1980 x 780 x 1950 mm
Note:External dimensions include top motor plenum and side return ducting. Himalayan Steel Industries custom-tailors flange profiles to fit any wall panel thickness (50 mm, 80 mm, 100 mm).

Cleanroom Construction & Architectural Design

cGMP sanitary fabrication details from our Baddi engineering works

Seamless Electropolished Worktop

The primary work bed is laser-cut from high-purity AISI 316L stainless steel, dished slightly to contain liquid accidental spills, and electropolished to Ra < 0.4 µm.

Anti-Vibration Motor Mounting

Dynamically balanced backward curved centrifugal blowers installed on elastomer vibration dampening isolators to prevent micro-vibrations during micro-pipetting.

Gel-Seal HEPA Clamping Assembly

Precision mechanical compression jacks apply even upward pressure against the fluid gel channel of the mini-pleat HEPA filter for absolute leak-tight sealing.

Aerosol DOP Challenge Manifold

Upstream aerosol injection port and challenge sample port located right on the front face for convenient calibration without moving the equipment.

Counterweighted Glass Front Sash

Smooth slide-balanced tempered safety glass with optical sash height sensors that trigger an alarm if opened beyond recommended operating aperture.

Rigid Stand with Leveling Pads

Welded tubular 304 SS tubular stand fitted with dual-locking polyurethane swivel castors and heavy-gauge vibration pads for solid stationary placement.

Standard Operating Protocol (cGMP SOP)

Standard operating guidelines and contamination control sequence

SOP REFERENCE GUIDE
Objective
To establish standard operational protocol for working inside the Himalayan Steel Vertical Laminar Air Flow workstation.
Scope
Applies to all aseptic manipulations, culture transfers, and clean compounding performed under VLAF hoods.
Responsibility
Microbiologists, Compounding Pharmacists, and Production Technicians.

Step-by-Step Material Transfer Sequence

1
Verify that the workstation power cord is securely plugged in and the main isolator is switched on.
2
Start the blower switch and check the Dwyer Magnehelic gauge (reading must register within 10–20 mm WC).
3
Allow the blower to purge the interior chamber for at least 15 minutes before introducing any materials.
4
Turn off the germicidal UV-C light (if on) and switch on the white LED cleanroom illumination.
5
Sanitize gloved hands and thoroughly wipe down the SS 316L worktable using 70% sterile IPA from back to front.
6
Transfer pre-sanitized articles into the workstation, taking care to position them at least 10 cm inside the front sash opening.
7
Perform sterile manipulations under direct downflow; avoid blocking airflow above critical open containers.
8
Upon completion of work, remove all materials, sanitize the work surface, and leave the blower running for 5 minutes before shutting down.

Sanitization & Wipe-Down Protocol

  • Wipe worktable before and after every batch using 70% IPA and sterile lint-free wipes.
  • Clean acrylic / glass sashes with non-abrasive cleanroom detergent.
  • Inspect and wash suction pre-filters monthly in purified water.

Fail-Safe Interlock Protection

  • UV lamp automatically shuts off if the front sliding sash is opened.
  • Audio-visual buzzer alarms if airflow drops below 0.35 m/s.

Optional Engineering Customizations

Site-specific hardware adaptations

  • Gas / vacuum service cock fittings with safety shut-off valves
  • Stainless steel intravenous (IV) infusion hanging bar with hooks
  • Front stainless steel armrest bar for operator ergonomic wrist support
  • Static-neutralizing ionizer bar for particulate elimination on plastics
  • Variable speed fan controller with auto air velocity compensation
  • FLAMEPROOF motor blower assembly for solvent-rich laboratories

Quality Validation Package (DQ/IQ/OQ)

Audit-ready documentation for US FDA and EU-GMP inspections

  • Design Qualification (DQ) Documentation & Mechanical GA Drawings
  • Installation Qualification (IQ) Protocol Checklists
  • Operational Qualification (OQ) Velocity Mapping & Test Records
  • HEPA Filter Integrity Scan Certificate (DOP/PAO < 0.01%)
  • Non-Viable Particle Count Certificate (ISO Class 5 Compliance)
  • Electrical Safety & High Voltage Flash Test Certificate

Cleanroom Design Highlights

  • Unidirectional downward airflow sweeps particulates away from sensitive sterile products
  • Seamless SS 316L worktop with coved corners prevents microbial colonization
  • Feather-touch soft control switches for blower, LED lighting, and germicidal UV-C tube
  • Lockable heavy-duty polyurethane caster wheels with integrated leveling foot studs

Target Pharmaceutical Applications

Sterile Compounding & Ophthalmic Formulation
Microbiology Inoculation & Culture Transfers
Ampoule & Vial Filling Pre-Assembly
PCR Preparation & DNA/RNA Amplification Setup
Electronic Semiconductor Component Assembly